Quality assurance testing of an explosives trace analysis laboratory--further improvements
Andrew Crowson1, Sean P Doyle, Clifford C Todd
1Forensic Explosives Laboratory, Defence Science and Technology Laboratory, Fort Halstead, Sevenoaks, Kent TN14 7BP, UK. acrowson@dstl.gov.uk
Abstract:
The Forensic Explosives Laboratory (FEL) operates within the Defence Science and Technology Laboratory (DSTL) which is part of the UK Government Ministry of Defence (MOD). The FEL provides support and advice to the Home Office and UK police forces on matters relating to the criminal misuse of explosives. During 1989 the FEL established a weekly quality assurance testing regime in its explosives trace analysis laboratory. The purpose of the regime is to prevent the accumulation of explosives traces within the laboratory at levels that could, if other precautions failed, result in the contamination of samples and controls. Designated areas within the laboratory are swabbed using cotton wool swabs moistened with ethanol water mixture, in equal amounts. The swabs are then extracted, cleaned up and analyzed using Gas Chromatographs with Thermal Energy Analyzer detectors. This paper follows on from a previous published paper describing the regime and summarizing subsequent results from approximately 6 years of tests. Lessons learned and improvements made over the period are also discussed. Monitoring samples taken from surfaces within the trace laboratories and trace vehicle examination bay have, with few exceptions, revealed only low levels of contamination, predominantly of RDX. Analysis of the control swabs, processed alongside the monitoring swabs, has demonstrated that in this environment the risk of forensic sample contamination, assuming all the relevant anti-contamination procedures have been followed, is so small that it is considered to be negligible. The monitoring regime has also been valuable in assessing the process of continuous improvement, allowing sources of contamination transfer into the trace areas to be identified and eliminated.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Quality Assurance
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Atomic Emission Spectroscopy: Overview