Related Experiment Video
Updated: Jul 14, 2026

A Porcine Model of Acute Respiratory Failure with a Continuous Infusion of Oleic Acid
Published on: March 8, 2024
Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the
Maxime Cannesson1, Yassin Attof, Pascal Rosamel
1Hospices Civils de Lyon, Department of Anesthesiology and Intensive Care, Louis Pradel Hospital, Claude Bernard Lyon I University, France. maxime_cannesson@hotmail.com
Background:
Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) are related to respiratory variations in pulse pressure (DeltaPP) and are sensitive to changes in preload. The authors hypothesized that DeltaPOP can predict fluid responsiveness in mechanically ventilated patients during general anesthesia.
Methods:
Twenty-five patients referred for cardiac surgery were studied after induction of general anesthesia. Hemodynamic data (cardiac index, central venous pressure, pulmonary capillary wedge pressure, DeltaPP, and DeltaPOP) were recorded before and after volume expansion (500 ml hetastarch, 6%). Fluid responsiveness was defined as an increase in cardiac index of 15% or greater.
Results:
Volume expansion induced changes in cardiac index (2.0+/-0.4 to 2.3+/-0.5 mmHg; P<0.05), DeltaPP (11+/-7 to 6+/-5%; P<0.05), and DeltaPOP (12+/-9 to 7+/-5%; P<0.05). DeltaPOP and DeltaPP were higher in responders than in nonresponders (17+/-8 vs. 6+/-4 and 14+/-7 vs. 6+/-4%, respectively; P<0.05 for both). A DeltaPOP greater than 13% before volume expansion allowed discrimination between responders and nonresponders with 80% sensitivity and 90% specificity. There was a significant relation between DeltaPOP before volume expansion and percent change in cardiac index after volume expansion (r=0.62; P<0.05).
Conclusions:
DeltaPOP can predict fluid responsiveness noninvasively in mechanically ventilated patients during general anesthesia. This index has potential clinical applications.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: