Objective:
Comparison of the bias and the limits of agreement (LOA; 2 SD) of the central venous saturation (S(cv)O(2)) before, during and after coronary artery bypass graft surgery with a simultaneous measurement of the mixed venous saturation (S(v)O(2)).
Design And Setting:
Prospective controlled study in a university hospital department of anaesthesiology.
Patients:
60 patients with coronary artery bypass surgery, 300 paired measurements of S(v)O(2) and S(cv)O(2).
Measurements And Results:
S(cv)O(2) and S(v)O(2) were analysed after induction of anaesthesia 15 min after cardiopulmonary bypass and 1, 6 and 18 h after admission to the intensive care unit. Regression analysis for the pooled measurements of S(cv)O(2) and S(v)O(2) showed a correlation R (2) = 0.52. After induction of anaesthesia 15 min after weaning from cardiopulmonary bypass and 6 h after admission to the intensive care unit the correlation coefficient was R (2) = 0.46, on admission to the intensive care unit it was R (2) = 0.42, and at 18 h it was R (2) = 0.38. Bland-Altman analysis for the measurements of S(cv)O(2) and S(v)O(2) showed a mean bias and LOA of 0.3% and -11.9 to +12.4%. In patients with a low S(cv)O(2) there was a trend to overestimate the S(v)O(2) by using the S(cv)O(2). The only factor that influenced the DeltaS(v)O(2) - S(cv)O(2) was the oxygen extraction rate (R (2) = 0.16). In patients with S(cv)O(2) below 70% this association was more pronounced (R (2) = 0.60).
Conclusions:
Our findings demonstrate that oxygen extraction rate is the major factor in the difference between S(v)O(2) and S(cv)O(2). Under certain circumstances S(cv)O(2) differed substantially from S(v)O(2). Therefore in selected patients both parameters should be monitored to exclude general or focal hypoperfusion.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...