Technical errors in MR arthrography

Juerg Hodler1

  • 1Radiology, Orthopaedic University Hospital of Balgrist, Forchstrasse 340, 8008 Zurich, Switzerland. juerg.hodler@balgrist.ch

Skeletal Radiology
|May 29, 2007
PubMed

Insights

This article addresses technical challenges in MR arthrography, covering contraindications, injection, contrast material, and imaging techniques. It offers solutions to common errors for improved diagnostic accuracy in joint imaging.

Area of Science:

  • Radiology
  • Medical Imaging

Background:

  • Magnetic Resonance (MR) arthrography is a key diagnostic tool for joint pathologies.
  • Technical challenges can compromise the accuracy and diagnostic yield of MR arthrography.

Purpose of the Study:

  • To identify and discuss potential technical problems encountered during MR arthrography.
  • To present solutions for common errors in MR arthrography procedures.

Main Methods:

  • Review of contraindications for MR arthrography.
  • Analysis of issues related to injection technique, contrast material, and MR imaging parameters.
  • Discussion based on author's experience and local procedural standards.

Main Results:

  • Identified contraindications include infection, reflex sympathetic dystrophy, bleeding disorders, avascular necrosis, and contrast allergy.
  • Injection errors can cause extra-articular contrast collections or leakage, leading to diagnostic difficulties.
  • Suboptimal contrast concentration, delayed imaging, and incorrect MR sequences degrade image quality and diagnostic value.

Conclusions:

  • Addressing technical issues in MR arthrography is crucial for accurate joint assessment.
  • Standardized protocols and careful technique can mitigate common errors and enhance diagnostic outcomes.