High-frequency electrocardiogram analysis in the ability to predict reversible perfusion defects during adenosine
Elin Trägårdh1, Todd T Schlegel, Marcus Carlsson
1Department of Clinical Physiology, Lund University Hospital, Lund, Sweden. Elin.tragardh@med.lu.se
Background:
A previous study has shown that analysis of high-frequency QRS components (HF-QRS) is highly sensitive and reasonably specific for detecting reversible perfusion defects on adenosine myocardial perfusion imaging (MPI) scans. The purpose of the present study was to try to reproduce those findings.
Methods:
Twelve-lead high-resolution electrocardiogram recordings were obtained from 100 patients before (baseline) and during adenosine (99m)Tc-tetrofosmin MPI tests. The HF-QRS were analyzed regarding morphology and changes in root mean square voltages from before the adenosine infusion to peak infusion.
Results:
The best area under the curve (AUC) was found in supine patients (AUC = 0.736) in a combination of morphology and root mean square changes. None of the measurements, however, were statistically better than tossing a coin (AUC = 0.5).
Conclusion:
Analysis of HF-QRS was not significantly better than tossing a coin for determining reversible perfusion defects on MPI scans.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Acute Coronary Syndrome III: Diagnostic Studies