Related Experiment Video
Updated: Jul 14, 2026

05:18
Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
The Hydro ThermAblator
1Department of Obstetrics and Gynecology, Thomas Jefferson University Medical School, Philadelphia, PA, USA. stephenlco@aol.com
Summary
The Hydro ThermAblator system offers effective endometrial ablation using heated saline and hysteroscopy. This minimally invasive treatment ensures patient satisfaction and excellent outcomes for abnormal uterine bleeding.
Area of Science:
- Gynecology
- Minimally Invasive Surgery
- Reproductive Medicine
Background:
- Abnormal uterine bleeding is a common gynecological issue.
- Endometrial ablation is a treatment option for heavy menstrual bleeding.
- Existing methods may have limitations in efficacy or safety.
Purpose of the Study:
- To evaluate the Hydro ThermAblator system for endometrial ablation.
- To assess the safety and efficacy of this novel approach.
Main Methods:
- Utilized the Hydro ThermAblator system with hysteroscopy and heated saline.
- Employed a 'no-touch' gravity flow technique for endometrial treatment.
- Incorporated an automated controller and a fluid level monitoring safety feature.
Main Results:
- Achieved excellent patient satisfaction rates.
- Demonstrated high amenorrhea rates and/or return to normal menstrual flow.
- The safety feature effectively detected potential uterine perforations.
Conclusions:
- The Hydro ThermAblator system provides a safe and effective endometrial ablation method.
- Reproducible results are achievable with minimal operator skill dependency.
- This system represents a significant advancement in managing abnormal uterine bleeding.
Related Concept Videos
Thermoregulation
The human body has a sophisticated thermoregulation system that employs negative feedback mechanisms to maintain an optimal core temperature. When the core temperature drops, peripheral and central thermoreceptors send signals to the hypothalamus, activating the heat-promoting center. This center triggers several responses aimed at increasing the core temperature. First, vasoconstriction reduces the flow of warm blood from internal organs to the skin so that the heat is not lost from the skin,...
Decreased Body Temperature
A decreased body temperature can occur in patients with hypothermia and frostbite. Heat loss with extended cold exposure overpowers the body's ability to create heat, resulting in hypothermia. Core temperature readings help classify hypothermia. Mild hypothermia is temperatures between 32 °C (89.6 °F) and 35°C (95 °F) and is caused by impaired thermoregulation. Moderate hypothermia is temperatures between 28 C (82.4 °F) and 32 °C (89.6 °F) caused by sustained extreme cold exposure, and severe...
Assessing Body Temperature - Rectal
Rectal temperature measurement is considered the most precise method for assessing core body temperature and typically registers higher than oral temperature. For adults, the rectal thermometer should be inserted 1 to 1.5 inches into the rectum to obtain the most accurate reading.
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermosensation
Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
Thermal Stress
If the temperature of an object is changed while it is prevented from expanding or contracting, the object is subjected to stress. The stress is compressive if the object expands in the absence of constraint and tensile if it contracts. This stress resulting from temperature change is known as thermal stress. It can be quite large and can cause damage. To avoid this stress, engineers may design components so they can expand and contract freely. For instance, on highways, gaps are deliberately...

