Related Experiment Video
Updated: Jul 14, 2026

Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm
Published on: August 1, 2025
Endovascular treatment of thoracoabdominal aortic aneurysms
Eric E Roselli1, Roy K Greenberg, Kathryn Pfaff
1Department of Thoracic and Cardiovascular Surgery, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA.
Objective:
To establish the safety and efficacy of endovascular repair of thoracoabdominal aortic aneurysms.
Methods:
Between May 2004 and February 2006, patients with thoracoabdominal aneurysms considered high risk for conventional surgery were enrolled in a prospective trial to evaluate a novel endovascular grafting system. Devices were custom designed for each patient using high-resolution computed tomography. Patient data included mortality, morbidity, procedural details, and surrogate end points for endovascular repair. These were collected at hospital discharge and at 1, 6, and 12 months.
Results:
Seventy-three patients underwent endovascular repair of thoracoabdominal aortic aneurysms for type I, II, or III (n = 28), or for type IV (n = 45) thoracoabdominal aneurysms. Mean aneurysm size was 7.1 cm (range 4.5-11.3 cm). General anesthesia was used in 47% of patients and regional anesthesia in 53%. There were no conversions to open surgery nor ruptures post-treatment. Technical success was achieved in 93% of patients (68/73). Thirty-day mortality was 5.5% (4/73). Major perioperative complications occurred in 11 (14%) patients and included paraplegia (2.7%, 2/73), new onset of dialysis (1.4%, 1/73), prolonged ventilator support (6.8%, 5/73), myocardial infarction (5.5%, 4/73), and minor hemorrhagic stroke (1.4%; 1/72). A majority of patients had no complications. Mean length of stay was 8.6 days. At follow-up, 6 deaths had occurred. There were no instances of stent migration nor aneurysmal growth.
Conclusions:
Endovascular repair of aortic aneurysms involving the visceral segment in nonsurgical candidates is feasible. Known complications of repair are not eliminated, but morbidity and mortality appeared low relative to the high-risk population studied. Further refinement of device design, delivery technique, and patient selection is ongoing. Assessment of durability will require longer follow-up.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Peripheral Artery Disease III: Interprofessional Care
Aortic Regurgitation III: Medical Management
Aneurysm I: Introduction