Comparison of divide and conquer and phaco-chop techniques during fluid-based phaco-emulsification
A Tsorbatzoglou1, L Módis, K Kertész
1Department of Ophthalmology, Medical and Health Science Center, Univ of Debrecen, Debrecen, Hungary. alex@jaguar.unideb.hu
Purpose:
To determine whether, similar to ultrasound phaco-emulsification, applied energy and surgery time decrease using phaco-chop nucleus fragmentation method compared to divide and conquer technique using the fluid-based system.
Methods:
This prospective, comparative, randomized clinical study included patients with cataract who were randomly assigned to use either standard divide and conquer technique (25 eyes of 25 patients, Group 1) or Nagahara phaco-chop maneuver (25 eyes of 25 patients, Group 2) during fluid-based phaco-emulsification. Surgical parameters were recorded and patients were examined 1 day, 10 days, and 1 month after surgery. Statistical analyses were performed using the paired test of Wilcoxon.
Results:
Fluid-based time, mean fluid-based magnitude, effective fluid-based time, and the number of pulses were significantly less using phaco-chop technique compared to divide and conquer method (p<0.001). Surgery time was similar using the two nucleofractis techniques (p=0.97). Visual acuities showed no statistical differences between the two groups (p>0.05).
Conclusions:
Nuclear fragmentation can be performed with Nagahara phaco-chop technique using the fluid-based system as well. The applied fluid-based energy decreases compared to divide and conquer method. However, surgery time is not reduced due to the difficulties reaching the full occlusion necessary to hold the nucleus during the chop maneuver.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...