[Measurement of arterial blood pressure using the sphygmomanometer-S and the direct method]
A Sapiński1, J Szuman, J Jasiński
1Poznańskiego Ośrodka Kardiopulmonologicznego.
Abstract:
Sphygmomanometer--S is the microcomputer device measuring blood pressure (BP) by the noninvasive sphygmooscillographic method following standard algorithm. When compared sphygmomanometer--S with auscultatory method, this device overestimated systolic BP by 7 mm Hg, and underestimated diastolic BP by 9 mm Hg on the average. In other words, sphygmomanometer--S overestimated systolic pressure and lowers diastolic pressure in relation to auscultatory method in the same ratio and value, as the direct method in relation to the auscultatory method. In this study, we evaluated the accuracy of the results obtained by sphygmomanometer--S, with simultaneously recorded radial artery pressure by direct method. In 15 patients 27-60 years of age undergoing cardiac surgery BP was measured by sphygmomanometer--S and direct method simultaneously on the same left upper extremity. We measured direct radial artery pressure using AE 840 Nycotron transducer and Philips amplifier. BP by sphygmomanometer--S was obtained on the same left arm using cuffs of size 11 x 24 cm and 13 x 35 cm. In 15 patients 124 pairs of BP measurement were carried out with sphygmomanometer--S and direct method. The regression equation for systolic, diastolic and mean pressure demonstrated the coincidence of the BP results obtained by sphygmomanometer--S with direct method. The correlation coefficient (r) was 0.97 for systolic, 0.90 for diastolic and 0.92 for mean pressure. Systolic and diastolic pressure measured by the sphygmomanometer--S were 2 mm Hg and mean 0.6 mm Hg higher on the average, than the same pressures obtained by direct method (ryc. 1). These differences were statistically not significant.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.