Detection and characterization of N-alpha-chloramines by electrospray tandem mass spectrometry

Mark J Raftery1

  • 1Bioanalytical Mass Spectrometry Facility, University of New South Wales, Kensington, New South Wales 2052, Australia. m.raftery@unsw.edu.au

Related Concept Videos

Mass Spectrometry of Amines01:15

Mass Spectrometry of Amines

In mass spectroscopy, amines undergo fragmentation to give parent ions with odd molecule weights. This observed mass spectrum follows the nitrogen rule; a molecule with an odd number of nitrogen atoms produces a molecular ion with an odd molecular weight. Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit strong molecular ion peaks, but acyclic aliphatic amines show...
Mass Spectrometry: Amine Fragmentation00:55

Mass Spectrometry: Amine Fragmentation

Amines can be identified using mass spectroscopy based on their characteristic fragmentation patterns. The molecular ions of amines undergo fragmentation via ⍺-cleavage. The ⍺-cleavage of the carbon-carbon bonds in amines generates an alkyl radical and resonance-stabilized nitrogen-containing cation.
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single or...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Mass Spectrometry: Alkyl Halide Fragmentation01:22

Mass Spectrometry: Alkyl Halide Fragmentation

Chlorine isotopes exist as 35Cl and 37Cl in a 3:1 ratio, while bromine isotopes exist as 79Br and 81Br in a 1:1 ratio. The mass spectrum of alkyl halides typically produces two distinct molecular ion peaks, the molecular ion peak, [M], and the molecular ion plus two, [M + 2] peak. The relative heights of these two peaks are proportional to the isotopic abundance ratios of the halide. For example, 2‐chloropropane and 1‐bromopropane display two peaks with relative peak heights in a 3:1 and 1:1...