Related Experiment Videos
Dose distributions in regions containing beta sources: uniform spherical source regions in homogeneous media
B L Werner1, M Rahman, W N Salk
1Department of Therapeutic Radiology, University of Minnesota Hospital and Clinic, Minneapolis 55455.
Medical Physics
|November 1, 1991
Abstract:
The energy-averaged transport model for the calculation of dose rate distributions is applied to uniform, spherical source distributions in homogeneous media for radii smaller than the electron range. The model agrees well with Monte Carlo based calculations for source distributions with radii greater than half the continuous slowing down approximation range. The dose rate distributions can be written in the medical internal radiation dose (MIRD) formalism.