Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability
Anders Johansson1, Michelle Chew
1Department of Anesthesia and Intensive Care, Lund University Hospital, Lund, Sweden. anders.johansson@omv.lu.se
Objective:
Arterial pulse contour analysis is gaining widespread acceptance as a monitor of continuous cardiac output (CO). While this type of CO measurement is thought to provide acceptable continuous measurements, only a few studies have tested its accuracy and repeatability under unstable hemodynamic conditions. We compared continuous CO measurement using the pulse contour method (PCCO) before and after calibration with intermittent transpulmonary thermodilution cardiac output (TpCO).
Method:
We compared the two methods of CO measurements in 15 Landrace pigs weighing 20-25 kg in an experimental model of sepsis. Nine pigs were given an infusion of E. coli lipopolysacchride (LPS), and six pigs acted as controls. PCCO values before and after calibration (PCCO1 and PCCO2 respectively) were registered, and their errors relative to TpCO measurements were compared.
Results:
The mean coefficient of variation for repeated PCCO measurements was 6.85% for the control group, and 13.99% for the endotoxin group. The range of TpCO was 1.01-3.15 L/min. In the control group the bias +/-2SD was 0.11 +/- 0.53 L/min (TpCO vs PCCO1) and -0.02 +/- 0.38 L/min (TpCO vs PCCO2). In the endotoxin group, the agreement was poor between TpCO and PCCO1, 0.08 +/- 1.02 L/min. This improved after calibration (TpCO vs PCCO2) to 0.01 +/- 0.31 L/min.
Conclusions:
In hemodynamically stable pigs, both pre- and post-calibration PCCO measurements agreed well with the intermittent transpulmonary thermodilution technique. However, during hemodynamic instability, and pre-calibration PCCO values had wide limits of agreement compared with TpCO. This was reflected by larger coefficients of variation for PCCO in hemodynamic instability. The error of PCCO measurement improved markedly after calibration, with bias and limits of agreement within clinically acceptable limits.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Special considerations while measuring pulse
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...