Related Experiment Video
Updated: Jul 14, 2026

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics
Published on: January 22, 2020
Different experimental results for the influence of immersion angle on the resonant frequency of a quartz crystal
Dazhong Shen1, Qi Kang, Xiaoyu Li
1School of Chemistry, Chemical Engineering and Material Science, Shandong Normal University, Jinan 250014, People's Republic of China. dzshen@sdnu.edu.cn <dzshen@sdnu.edu.cn>
Abstract:
This paper presents different experimental results of the influence of an immersion angle (theta, the angle between the surface of a quartz crystal resonator and the horizon) on the resonant frequency of a quartz crystal microbalance (QCM) sensor exposed one side of its sensing surfaces to liquid. The experimental results show that the immersion angle is an added factor that may influence the frequency of the QCM sensor. This type of influence is caused by variation of the reflection conditions of the longitudinal wave between the QCM sensor and the walls of the detection cell. The frequency shifts, measured by varying theta, are related to the QCM sensor used. When a QCM sensor with a weak longitudinal wave is used, its resonant frequency is nearly independent of theta. But, if a QCM sensor with a strong longitudinal wave is employed, the immersion angle is a potential error source for the measurements performed on the QCM sensor. When the reflection conditions of the longitudinal wave are reduced, the influence of theta on the resonant frequency of the QCM sensor is negligible. The slope of the plot of frequency shifts (deltaF) versus (rho eta)(1/2), the square root of the product of solution density (rho) and viscosity (eta), may be influenced by theta in a single experiment for the QCM sensor with a strong longitudinal wave in low viscous liquids, which can however, be effectively weakened by using the averaged values of reduplicated experiments. In solutions with a large (rho eta)(1/2) region (0-55 wt% sucrose solution as an example, with rho value from 1.00 to 1.26 g cm(-3) and eta value from 0.01 to 0.22 g cm(-1) s(-1), respectively), the slope of the plot of deltaF versus (rho eta)(1/2) is independent of theta even for the QCM sensor with a strong longitudinal wave in a single experiment. The influence of theta on the resonant frequency of the QCM sensor should be taken into consideration in its applications in liquid phase.
More Related Videos
07:11Dissipative Microgravimetry to Study the Binding Dynamics of the Phospholipid Binding Protein Annexin A2 to Solid-supported Lipid Bilayers Using a Quartz Resonator
Published on: November 1, 2018
11:34Epitaxial Nanostructured α-Quartz Films on Silicon: From the Material to New Devices
Published on: October 6, 2020