The effect of computed tomographical gantry angle on the measurement of the canine intercondylar notch
T W H Sellmeyer1, D A Allen, E R Wilson
1Mission MedVet, Mission, Kansas 66202, USA.
Abstract:
This study was conducted to evaluate the clinical application of computed tomography of the canine femoral intercondylar notch. The canine femoral intercondylar notch is angled 12 degrees from the dorsal plane and obliqued 7 degrees proximolateral to distomedial in the sagittal plane. Measurements of the notch were performed with eight, 12, and 16 degrees of gantry tilt. With the exception of proximal opening notch angle, significant differences were not detected in measurements referenced to 12 degrees of gantry tilt. Evidence from this study indicated that a +/- 4 degree variation in gantry tilt angle from a desired angle of 12 degrees did not significantly affect clinical interpretations of intercondylar notch measurements or notch width index ratios.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography