Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Assessment of orthostatic fluid shifts with strain gauge plethysmography
Roland D Thijs1, Maaike Bruijnzeels, Adriaan M Kamper
1Department of Neurology and Clinical Neurophysiology, Leiden University Medical Centre, PO Box 9600, 2300 RC Leiden, The Netherlands. r.d.thijs@lumc.nl
Abstract:
We evaluated the use of strain gauge plethysmography (SGP) for the assessment of orthostatic fluid shifts during head up tilt (HUT). Subjects wore a parachute harness fixed to the tilt table to avoid muscle tension in the lower limbs during HUT. 22 Healthy subjects (9 women) were tilted for 5 minutes. Calf volume changes as measured by SGP, surface EMG, heart rate and blood pressure were measured continuously. Ten subjects underwent a second tilt test during which circulation in one leg was occluded with a pressure cuff at 250 mmHg. During HUT with occlusion, calf volume increased in the non-occluded leg by 1.9+/-0.3% (mean +/- SEM) and 0.2+/-0.2% in the occluded leg (p<0.001). During HUT without occlusion a significant correlation (r = 0.9) was found between measurements of the left and right leg with a mean difference of 0.03+/-0.1%. HUT did not cause significant changes of surface EMG. An unexpected gender effect was found: calf volume increased significantly more in men than in women. Men were significantly taller, but the hemodynamic response to HUT did not differ between both sexes. The gender effect on orthostatic increases of calf volume remained significant after adjustment for heart-to-calf distance. SGP during HUT with a parachute harness is a new, promising method to assess orthostatic fluid shifts. The gender differences in orthostatic pooling in the calf may be explained by a higher calf compliance in men together with a greater hydrostatic pressure due to a greater height in men.
Related Concept Videos
Measurements of Strain
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure in the Leg
Preparation: