Related Experiment Video
Updated: Jul 14, 2026

The Frequency Domain Thermoreflectance Technique for Thermal Property Measurements
Published on: December 5, 2025
Spatiotemporal temperature fluctuation measurements by means of a fast swept Langmuir probe array
M Schubert1, M Endler, H Thomsen
1Max-Planck-Institut für Plasmaphysik, Wendelsteinstrasse 1, Greifswald 17491, Germany. martin.schubert@lpmi.uhp-nancy.fr
Abstract:
Stationary Langmuir probe measurements of ion saturation current and floating potential in a plasma cannot give direct information on density and plasma potential fluctuations in the presence of temperature fluctuations. This problem can be avoided if the probe bias voltage is continuously swept faster than the fluctuation time scale, recording the current-voltage characteristic. This article reports the development of a spatiotemporal highly resolving Langmuir probe array with 15 fast swept tips, operating in the strongly magnetized, collisionless edge plasma of the Wendelstein 7-AS stellarator [Plasma Phys. Controlled Fusion 31, 1579 (1989)]. The probe tips are aligned in the poloidal direction, the tip spacing is 2 mm, and the sweeping frequency is 1.4 MHz. Current and voltage data are sampled with 50 MHz. The high bandwidth of the measurement is achieved by placing miniaturized differential amplifiers close to the probe tips in order to do an impedance transform. The surface-mounting technology and an additional inverse feedback module are utilized, allowing for an input voltage range of +/-100 V, and a common mode rejection rate of 55 dB at 4 MHz, which is sufficient to resolve the nonlinear probe characteristic. For the evaluation of the data, a fit model for stationary probes is employed and found adequate. Changes of the plasma parameters during one voltage sweep are taken into account by a linear interpolation of the fit parameters. Spatio-temporal fluctuation data gained by a fast swept Langmuir probe array, which can be relevant for the turbulent radial transport of particles and energy, are presented.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

