Validation of LAB color mode as a nondestructive method to differentiate black ballpoint pen inks
1U.S. Army Criminal Investigation Laboratory, Forensic Document Branch, 4930 N. 31st Street, Forest Park, GA 30297-5205, USA. derek.hammond@us.army.mil
Abstract:
Nondestructive digital processing methods such as lab color mode (available in Adobe Photoshop) are emerging as alternative methods for forensic document examiners to use when attempting to differentiate writing instrument inks. Although these techniques appear to be viable, little data currently exists regarding the known or potential error rates associated with these techniques. Without adequate data, the validity and reliability of these techniques, including lab color, can not be established. In an attempt to begin to address these issues, 44 black ballpoint ink pens were obtained and used to create 990 pen-pair samples for analysis using established lab color mode techniques. No erroneous findings of "different" were reported following the examination of the known pen-pair combinations in which the same pen was used to create the samples (n = 44). Of the remaining 946 samples, 737 pen-pair samples were differentiated using the lab color mode method, while 209 samples were unable to be differentiated and were recorded as either being "similar" (n = 153) or "unsure" (n = 56). Comparison of the lab color mode results with the results obtained through additional testing using traditional infrared reflectance and infrared luminescence test methods showed that lab color differentiated 102 pen-pair samples (11%; 102/946) that were not differentiated using a VSC-4C.
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Differential Staining Technique
Simple Staining Technique
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Special Staining Techniques