Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Quantitative determination of ethanol in heated plumes by passive Fourier transform infrared remote sensing
1Department of Chemistry & Optical Science and Technology Center, University of Iowa, Iowa City, IA 52242, USA.
Abstract:
Quantitative calibration models are developed for passive Fourier transform infrared (FT-IR) remote sensing measurements of open-air-generated vapors of ethanol. These experiments serve as a feasibility study for the use of passive FT-IR measurements in quantitative determinations of industrial stack emissions. A controlled-temperature plume generator is used to produce plumes of known concentrations of pure ethanol and mixtures of ethanol and methanol. Analyte plumes are generated over the path-averaged concentration range of 20-300 ppm-m and stack temperatures of 125, 150, 175, and 200 degrees C. A novel experimental setup is employed in which an ambient temperature polyvinyl chloride backdrop is placed behind the emission stack and used as a target for the passive IR measurements. An emission FT-IR spectrometer with telescope entrance optics is then employed to view the generated plumes against the backdrop. Signal processing techniques based on signal averaging and bandpass digital filtering are applied to both interferogram and single-beam spectral data obtained from these measurements, and the resulting filtered signals are used as inputs into the generation of multivariate partial least-squares (PLS) calibration models. Successful calibration models are obtained with both interferogram and spectral data, and neither analysis requires the collection of separate IR background data. For a set of validation data collected on a different day from the calibration measurements, standard errors of prediction of 30.6 and 32.2 ppm-m ethanol are obtained for the PLS models based on interferogram and spectral data, respectively.
More Related Videos
07:17Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
Published on: August 1, 2017
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrometers
Flame Photometry: Lab
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
IR Frequency Region: Fingerprint Region
The...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...