Related Experiment Video
Updated: Jul 14, 2026

In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
[Measurement of CO2 using an open-path FTIR and the factor of influence]
Xiu-li Wei1, Yi-huai Lu, Min-guang Gao
1Chinese Academy of Science, Anhui Institute of Optic Fine Machines, Hefei 230031, China. xlwei@aiofm.ac.cn
Abstract:
In the remote-sensing experiments of CO2 in Beijng, the authors found that the higher concentration of CO2 in autumn is caused by the CO2 emission by the traffic sector during the day time. During the day time, the concentratration of CO2 is comparatively lower because of the photochemistry and the transportation of troposphere. And the concentration of CO2 is about 410 microg x mL(-1). At night the fossil fuel power plants will be taken as a model for the source of CO2, so the concentration of CO2 is about 610 microg x mL(-1) or higher. The carbon increment from increased photosynthesis is greater than the increment in ecosystem carbon stocks. The higher the temperature, the lower the CO2 concentration. And the lower the rate of wind, the higher the concentration of CO2 also. Besides, the concentration of CO2 is affected by some other weather factors.
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
Voltammetry: Factors Affecting Measurements
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a decrease in the...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Measurement of Air Content in Concrete
The pressure method,...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...