Related Experiment Video
Updated: Jul 14, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Dose assessment for ingestion of a 330 kilobecquerel 60Co hot particle
D W Whillans1, W J Chase, W H Wolodarsky
1Health Physics Department, Ontario Power Generation, Whitby, Ontario, Canada L1 N 9E3. david.whillans@opg.com
Abstract:
On leaving the irradiated fuel bay at Pickering A nuclear power station, a worker triggered a whole body monitor alarm with activity in or on his head, and despite careful decontamination techniques he subsequently swallowed a hot particle. Over the next 3 d, the radioactivity was tracked through the body. It was then excreted in a single faecal sample and recovered for physical and radiochemical analysis. This analysis demonstrated that the particle contained 330 kBq of 60Co and only traces of other radioactivity. Its dimensions were approximately 50-130 microm and its composition was consistent with that of Stellite 6. A dose assessment was carried out taking into account the residence time of the particle in the mouth and its transit through the body. The estimated committed effective dose was 1.4 mSv, and the equivalent dose to the maximally exposed 1 cm2 of skin, 81 mSv.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:52Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Dose Size and Dosing Frequency: Determination Methods
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Dose-Response Relationship: Overview