Identification of bacteria from two-dimensional resonant-Raman spectra

Analytical Chemistry
|June 15, 2007
PubMed

Related Concept Videos

Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Rapid Identification of Pathogens01:25

Rapid Identification of Pathogens

MALDI-TOF MS has transformed clinical microbiology by offering a rapid and reliable method for pathogen identification. The traditional approach to microbial identification typically involves time-consuming culture techniques and biochemical tests, which can delay the initiation of appropriate antimicrobial therapy. MALDI-TOF MS avoids these delays by using characteristic ribosomal protein mass patterns of microbial cells, enabling accurate species-level identification within minutes.Principle...
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
Methods of Classification and Identification01:28

Methods of Classification and Identification

Bacterial identification relies on a diverse array of techniques to classify and understand microorganisms, each tailored to uncover specific characteristics. Traditional morphological approaches, while still valuable, are limited for closely related or structurally simple organisms. Modern methods integrate biochemical, serological, genetic, and advanced molecular tools to achieve greater accuracy.Morphological and Biochemical TechniquesMorphological characteristics, such as cell shape and...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...