Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Development, validation and application of a method to analyze phenols in water samples by solid phase micro
Fernando M Lanças1, Igor R B Olivares, Priscila M Alves
1São Paulo University, Institute of Chemistry at São Carlos, São Paulo University, São Carlos, SP, Brazil. flancas@iqsc.usp.br
Abstract:
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70 degrees C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 microg.L(- 1)); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 microg.L(- 1)). After the methodology development, samples of water collected in Atibaia River (São Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.
More Related Videos
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.