Related Experiment Video
Updated: Jul 14, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Diffusion-weighted MRI in prostate cancer -- comparison between single-shot fast spin echo and echo planar imaging
Piotr Kozlowski1, Silvia D Chang, S Larry Goldenberg
1Prostate Centre at Vancouver General Hospital, Vancouver, British Columbia, Canada V6H 3Z6. pkozlow@interchange.ubc.ca
Diffusion-weighted MRI using Echo Planar Imaging (EPI) yields higher apparent diffusion coefficient (ADC) values than Fast Spin Echo (FSE) sequences. This finding is significant for prostate cancer (PCa) detection and characterization.
Area of Science:
- Radiology
- Medical Imaging
- Oncology
Background:
- Diffusion-weighted (DW) MRI is crucial for prostate cancer (PCa) diagnosis.
- Comparing MRI sequences like Fast Spin Echo (FSE) and Echo Planar Imaging (EPI) is essential for optimizing diagnostic accuracy.
- Understanding apparent diffusion coefficient (ADC) variations across different prostate zones and pathologies is key.
Purpose of the Study:
- To compare the performance of single-shot FSE and single-shot EPI sequences in DW MRI for prostate cancer detection.
- To evaluate differences in ADC values between normal prostate tissues and prostate carcinoma (PCa) using both sequences.
- To determine if EPI or FSE sequences provide more significant ADC variations.
Main Methods:
- Diffusion-weighted MRI at 1.5 T was performed on two patient groups using single-shot FSE (14 patients) and single-shot EPI (15 patients).
- MRI data were correlated with biopsy and histopathology results.
- Average ADC values (x 10(-3) mm(2)/s) were calculated for the peripheral zone (PZ), central gland (CG), and prostate carcinoma (PCa) using b values of 0 and 600, with statistical analysis via Tukey-Kramer test.
Main Results:
- Both EPI and FSE sequences demonstrated significant differences in ADC values between normal PZ, CG, and PCa.
- EPI sequences produced significantly higher ADC values compared to FSE sequences across all regions: PZ (1.992±0.208 vs. 1.573±0.270, P<.001), CG (1.518±0.126 vs. 1.373±0.179), and PCa (1.214±0.254 vs. 0.993±0.158, P<.01).
Conclusions:
- Both EPI and FSE DW MRI sequences can differentiate between normal prostate zones and prostate carcinoma based on ADC values.
- The EPI sequence yields significantly higher ADC values than the FSE sequence, suggesting potential advantages for lesion detection or characterization in prostate MRI.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...

