Photon-independent gas-phase-ion formation in capillary electrophoresis-mass spectrometry using atmospheric pressure photoionization
Related Experiment Video
Updated: Jul 14, 2026

Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
Published on: July 27, 2018
Paul Hommerson1, Amjad M Khan, Tony Bristow
1Department of Biomedical Analysis, Utrecht University, P.O. Box 80082, 3508 TB Utrecht, The Netherlands. P.Hommerson@uu.nl
Abstract:
In a previous study on capillary electrophoresis-atmospheric pressure photoionization mass spectrometry (CE-APPI-MS), it was observed that the formation of gas-phase ions does not always proceed through photon-induced mechanisms (Hommerson, P.; Khan, A. M.; De Jong, G. J.; Somsen, G. W. Electrophoresis 2007, 28, 1444-1453). That is, analyte signals were observed when the VUV excitation source was switched off. The aim of the present study was to further explore this photon-independent ionization (PII) process. Parameters such as MS capillary voltage, compound nature, background electrolyte (BGE) composition, and presence of dopants were studied using a CE-APPI-MS setup. Infusion experiments showed a relatively low MS capillary voltage of approximately 600 V to be the main prerequisite for PII. Quaternary ammonium compounds showed strong responses in PII-MS but could not be observed in dopant-assisted APPI. Basic amines could be ionized by both photoionization (PI) and PII, whereas neutral compounds (steroids) could only be observed using PI. Nonvolatile BGEs appeared to cause substantial ionization suppression in PII, while PI signals remained largely unaffected. Selection of the proper interface and MS settings allowed PI and PII to proceed simultaneously, which broadened the range of compounds that could be analyzed in a single CE-APPI-MS run. Based on the observed characteristics, it is concluded that PII most probably occurs by a liquid-phase ionization mechanism, which appears to arise in the APPI source when specific conditions are selected.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Capillary Electrophoresis: Instrumentation
Mass Spectrum: Interpretation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...