Related Experiment Video
Updated: Jul 14, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Patient-specific scaling of reference S-values for cross-organ radionuclide S-values: what is appropriate?
Nina Petoussi-Henss1, W E Bolch, M Zankl
1GSF-National Research Center for Environment and Health, Institute of Radiation Protection, Ingolstaedter Landstr. 1, 85764 Neuherberg, Germany. petoussi@gsf.de
Abstract:
The Medical Internal Radiation Dose Committee (MIRD) formalism assumes reference mass values for the organs (source and target) and the total body. MIRD publication 11 provides guidance on how patient-specific scaling of reference radionuclide S-values are to be performed for the electron component of the emission spectrum. However, guidance on patient-specific scaling of the photon contributions to the S-value is given only for those cases where the source and target organs are either far apart or are the same. The photon component of the S-value is derived from photon-Specific Absorbed Fractions (SAFs). These are obtained by Monte Carlo calculation of photon transport. The objective of this work is to verify the MIRD 11 guidance and to examine the relationship between photon SAFs and source/target organ mass when the conditions listed above do not apply. Furthermore, the scaling for photon cross-dose to distributed organs is at present not defined due to lack of data for models other than the reference model. The validity of mass scaling for cross irradiation from near and distant photons sources, especially for Red Bone Marrow (RBM) as a target tissue is also investigated. This is achieved by comparing Monte Carlo-derived SAFs for different source organs to RBM across the GSF voxel phantom series. The results show that, for photon energies greater than 100 keV, the SAF of most source organs to RBM need not be corrected for target mass (error < 5%). In contrast to the results obtained for well-defined source organs, the SAF for RBM irradiating RBM gives a deviation of up to 16% across the different GSF voxel phantoms.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022