Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration
Berthold Bein1, Patrick Meybohm, Erol Cavus
1Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany. bein@anaesthesie.uni-kiel.de
Background:
Reliable measurement of cardiac output (CO) is important in the critically ill. Pulse contour-derived CO (PCCO) has been evaluated during stable hemodynamics, but is sensitive to changes in vascular tone and has not been validated under conditions of changing hemodynamics. Furthermore, PCCO requires calibration for the individual vascular impedance by transpulmonary thermodilution CO (TPCO), and the required frequency of recalibration to maintain accurate measurements, especially during changing conditions, has not been confirmed. We compared PCCO measurements of CO with TPCO and continuous and bolus pulmonary artery CO (CCO and BCO, respectively) during conditions of uncontrolled hemorrhage and resuscitation with norepinephrine.
Methods:
Thirteen pigs were anesthetized and instrumented for determination of CO by BCO and CCO, respectively, as well as bolus TPCO and PCCO. Uncontrolled hemorrhage was accomplished by liver incision. When mean arterial blood pressure was <25 mm Hg, or heart rate declined progressively to <20% of its peak value, vasopressor therapy was started. TPCO and BCO were performed after induction of anesthesia and 15 min after start of therapy, and PCCO and CCO were obtained repeatedly. CO measurements were compared using Bland-Altman analysis.
Results:
Mean arterial blood pressure, CO and systemic vascular resistance decreased after hemorrhage (P < 0.001 and <0.01, respectively). Bias and limits of agreement between CCO and PCCO (0.54 L/min; 1.46 L/min) increased after hemorrhage (-3.49; 6.12) and further deteriorated after norepinephrine administration (-8.01; 9.9). After recalibration, bias and limits of agreement returned to -0.51 and 1.28.
Conclusions:
PCCO needs frequent recalibration during hemorrhage and after vasopressor administration.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse
The pulse serves as a clinical indicator...
Measurement of Blood Pressure
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...