Previous studies of laboratory simulation of high temperature, short time pasteurization (HTST) to eliminate foot-and-mouth disease virus (FMDV) in milk have shown that the virus is not completely inactivated at the legal pasteurization minimum (71.7 degrees C/15 s) but is inactivated in a flow apparatus at 148 degrees C with holding times of 2 to 3 s. It was the intent of this study to determine whether HTST pasteurization conducted in a continuous-flow pasteurizer that simulates commercial operation would enhance FMDV inactivation in milk. Cows were inoculated in the mammary gland with the field strain of FMDV (01/UK). Infected raw whole milk and 2% milk were then pasteurized using an Arm-field pilot-scale, continuous-flow HTST pasteurizer equipped with a plate-and-frame heat exchanger and a holding tube. The milk samples, containing FMDV at levels of up to 10(4) plaque-forming units/mL, were pasteurized at temperatures ranging from 72 to 95 degrees C at holding times of either 18.6 or 36 s. Pasteurization decreased virus infectivity by 4 log10 to undetectable levels in tissue culture. However, residual infectivity was still detectable for selected pasteurized milk samples, as shown by intramuscular and intradermal inoculation of milk into naïve steers. Although HTST pasteurization did not completely inactivate viral infectivity in whole and 2% milk, possibly because a fraction of the virus was protected by the milk fat and the casein proteins, it greatly reduced the risk of natural transmission of FMDV by milk.
Related Concept Videos
Pasteurization and Food Preservation
Physical Methods for Controlling Microbial Growth: Temperature
Microbes in Food Production
Methods of Controlling Food Spoilage
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Microbial Spoilage of Food