Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
[Monitoring of breathing pattern at rest by electrical impedance tomography]
Marco Balleza1, Jaume Fornos, Núria Calaf
1Unitat de Funció Pulmonar, Departament de Pneumologia, Hospital de la Santa Creu i de Sant Pau, Facultat de Medicina, Universitat Autònoma de Barcelona, Barcelona, Spain. jballeza@santpau.es
Objective:
Electrical impedance tomography (EIT) involves the application of a small alternating current to produce a series of chest images that can be used to monitor breathing pattern. The relation between chest images and tidal volume has not been sufficiently validated. The aim of the present study was to analyze the correlation between EIT images and the volume-time signal measured with a pneumotachometer in 13 healthy volunteers.
Material And Methods:
The following measurement devices were used: a) MedGraphics preVent Pneumotach, with special software for recording the volume-time signal (reference test), and b) EIT-4, a fourth-generation prototype unit designed by the Department of Electronic Engineering at the Universidad Politécnica de Cataluña, Spain that records the volume-time signal and produces a graphic depiction of a cross section of the thorax at the sixth intercostal space.
Results:
The mean (SD) tidal volume measured by the pneumotachometer and the EIT-4 was 0.523 (0.102) L and 0.527 (0.106) L, respectively (P value not significant). The linear correlation coefficient between the 2 measurements was 0.923 (P=.001), and the mean of the differences between the 2 procedures was -0.003 L (95% confidence interval, -0.045 to 0.038). The greatest differences were associated with female gender, body mass index, and chest circumference. In view of these differences, a different equation based on these variables was needed for calibration of the EIT-4.
Conclusions:
The EIT-4 provides an alternative means of monitoring breathing pattern, although a number of issues related to the circumference of the rib cage need to be resolved.
More Related Videos
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Respiratory Volumes and Capacities I
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...