Investigation of characterization method for nanoparticles in roadside atmosphere by thermal desorption-gas
Akihiro Fushimi1, Kiyoshi Tanabe, Shuichi Hasegawa
1Environmental Chemistry Division, National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba 305-8506, Japan. fushimi.akihiro@nies.go.jp
Abstract:
Atmospheric nanoparticles (<0.050 microm) have caused great concern recently due to their potential to affect human health. However, little is known about the chemical composition, sources, and atmospheric behavior of atmospheric nanoparticles. Although gas chromatography/mass spectrometry (GC/MS) after solvent extraction is a commonly used and powerful method for the identification of nonpolar organic compounds in particles, solvent-extraction methods are difficult to apply to nanoparticles because nanoparticles are present in small masses in spite of their high number concentrations. Therefore, we made an attempt to apply thermal desorption-GC/MS (TD-GC/MS), which was expected to be more sensitive than solvent-extraction methods, to atmospheric nanoparticles. A commercial pyrolyzer was used for TD. Prior to the application, the optimum TD-GC/MS conditions for atmospheric particles and diesel exhaust particles (DEP) collected on filters were investigated. Various TD parameters, including desorption time and temperature, were investigated using these test samples and a n-alkanes standard solution. The optimum TD conditions were as follows: ramped desorption from 50 degrees C to 450 degrees C at 50 degrees C min(-1) and then hold for 2 min. Desorption was incomplete at temperatures of 250 degrees C or lower, and considerable pyrolysis occurred at temperatures of 550 degrees C or higher. The TD-GC/MS performance, including the linearity of the calibration curves, repeatability, detection and quantification limits, and sample recovery, under the optimized conditions was evaluated for n-alkanes. It was found that the TD-GC/MS could be applied to extremely small amount of particles (e.g., 5 microg for DEP). The TD-GC/MS was applied to the size-resolved particles, including the nanoparticle fraction (0.0290-0.0580 microm), from roadside atmosphere, and the concentrations of C18-C33 n-alkanes in the particles were determined. The chromatogram pattern of the roadside 0.102-0.163 microm (major size range for DEP) particles was similar to that of the DEP sample. The chromatogram pattern of the roadside nanoparticles was similar to that of diesel lubricating oil, although the proportion of less volatile compounds was slightly larger in the nanoparticles. It is suggested that lubricating oil strongly contributed to the nonpolar organic composition of the roadside nanoparticles, and that more volatile organic compounds in the nanoparticles evaporated in the atmosphere. It was shown that the TD-GC/MS is effective for characterization of atmospheric nanoparticles.
More Related Videos
08:07A Two-Step Pyrolysis-Gas Chromatography Method with Mass Spectrometric Detection for Identification of Tattoo Ink Ingredients and Counterfeit Products
Published on: May 22, 2019
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Flame Photometry: Lab
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...