Updated: Jul 14, 2026

Application of the En Bloc Concept Combined with Anatomic Resection in Laparoscopic Hepatectomy
04:41

Application of the En Bloc Concept Combined with Anatomic Resection in Laparoscopic Hepatectomy

Published on: March 10, 2023

A standardized safe hepatectomy; selective Glissonean transection using endolinear stapling devices.

Masahiko Fujii1, Mitsuo Shimada, Imura Satoru

  • 1Department of Surgery, Institute of Health Biosciences, The University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima City 770-8503, Japan.

Hepato-Gastroenterology
|June 27, 2007
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Koilocytosis in LSIL Cytology Has Limited Predictive Value for CIN2+ in HPV-Positive Women: Implications for Risk-Based Cytology Triage.

Pathogens (Basel, Switzerland)·2026
Same author

Successful minimally invasive valve repair for isolated severe tricuspid regurgitation due to infective endocarditis.

JTCVS techniques·2025
Same author

Unintentional False Lumen Placement of Frozen Elephant Trunk in Aortic Dissections: Root Cause Analysis of Morphological Risk Factors.

European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery·2025
Same author

Left-sided valve dysfunction with extreme giant left atrium and anomalous coronary sinus connection after atrioventricular septal defect repair.

JTCVS techniques·2025
Same author

Vacuolated Parabasal Cells in Papanicolaou Smears Are Cellular Changes Caused by Human Papillomavirus 16 Infection.

Journal of medical virology·2025
Same author

Safety and efficacy of surgical revascularization with percutaneous ventricular assist device for acute myocardial infarction complicated by cardiogenic shock: Japanese national registry study.

Artificial organs·2024

Selective Glissonean pedicle transection using surgical staplers offers a safe and effective method for liver resection. This technique reduces operative time and complications, improving patient outcomes in hepatectomy procedures.

Area of Science:

  • Hepatobiliary Surgery
  • Surgical Oncology
  • Gastroenterology

Background:

  • Systematized hepatectomy relies on selective Glisson's pedicle clamping.
  • Surgical staplers are widely adopted for Glissonean transection.
  • Accidental stapling of the biliary confluence remains a risk.

Observation:

  • A case of selective Glissonean pedicle transection using an endolinear stapling device was reported.
  • The technique was applied to five patients, with no major complications.
  • A 71-year-old woman with hepatocellular carcinoma underwent right hepatic lobectomy.

Findings:

  • Independent division of Glisson's pedicle anterior and posterior branches using an endolinear stapling device.
  • Right hepatic lobectomy was completed with minimal bleeding.

More Related Videos

Right Hemihepatectomy by Suprahilar Intrahepatic Transection of the Right Hemipedicle using a Vascular Stapler
03:45

Right Hemihepatectomy by Suprahilar Intrahepatic Transection of the Right Hemipedicle using a Vascular Stapler

Published on: January 25, 2010

Related Experiment Videos

Last Updated: Jul 14, 2026

Application of the En Bloc Concept Combined with Anatomic Resection in Laparoscopic Hepatectomy
04:41

Application of the En Bloc Concept Combined with Anatomic Resection in Laparoscopic Hepatectomy

Published on: March 10, 2023

Right Hemihepatectomy by Suprahilar Intrahepatic Transection of the Right Hemipedicle using a Vascular Stapler
03:45

Right Hemihepatectomy by Suprahilar Intrahepatic Transection of the Right Hemipedicle using a Vascular Stapler

Published on: January 25, 2010

  • Shortened operation time and uneventful postoperative course were observed.
  • Implications:

    • Standardized selective Glissonean transection with endolinear stapling devices promotes safe hepatectomy.
    • Reduced operative time and complication risk contribute to improved short-term outcomes.
    • This technique is beneficial for patients, especially those with liver cirrhosis.