Development of an In Vitro Ocular Platform to Test Contact Lenses
Published on: April 6, 2016
Corneal oxygen distribution with contact lens wear
Larry A Alvord1, W Jordan Hall, L David Keyes
1CIBA Vision Corporation, Duluth, GA 30097, USA.
Purpose:
Since 1991, multilayer mathematical in vivo oxygenation models have been created to predict normal corneal oxygenation with contact lens wear. From these models, there have been assertions that most hydrogel contact lenses allow 97%-98% of normal corneal oxygenation compared to no contact lens wear. In light of hydrogel lens-induced neovascularization and limbal hyperemia, to clinicians, this finding seems counterintuitive. This work seeks to validate or refute those preexisting models and estimate the impact of contact lens wear on the oxygen distribution profile across the cornea. To this end, to estimate the impact of contact lens wear on the 3-dimensional (3-D) oxygen distribution profile within the cornea as a function of the oxygen permeability of the contact lens, a two-dimensional axisymetric finite element analysis (FEA) model was constructed for contact lenses, on the cornea, both having varying thickness profiles.
Methods:
A two dimensional (2-D) axi-symetric finite element analysis (FEA) model of a -3.00 D contact lens on eye was constructed. The model included the varying thickness profiles of the contact lens and cornea. By symmetry, this 2-D model is equivalent to a full 3-D model. The oxygen permeability, material thickness profile, and oxygen consumption coefficients from Brennan (Optometry and Vision Science, June 2005) were used for this validation. Several different oxygen consumption profiles were also considered. Oxygen partial pressure, flux, and consumption profiles were generated.
Results:
Profiles of the oxygen partial pressure, flux, and consumption were generated from the central cornea to the limbal junction.
Conclusion:
This FEA model reproduced Brennan 8-layer model (BEL model) results at the central cornea. However, BEL model parameters yielded regions of oxygen deficiency in the corneal periphery, even in the open eye with no contact lens. If the BEL model cannot account for oxygenation across the whole cornea, it may be incorrect or incomplete. This assertion calls into question any conclusions from the BEL model regarding the minimum contact lens transmissibility needed to fully oxygenate the eye.
More Related Videos
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Transport in the Blood
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Ophthalmic Drug Delivery Systems
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.