Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Evaluation of mechanisms of postflight orthostatic intolerance with a simple cardiovascular system model
Justin Broskey1, M Keith Sharp
1Biofluid Mechanics Laboratory, Department of Mechanical Engineering, University of Louisville, 200 Sackett Hall, Louisville, KY 40292, USA.
Abstract:
A significant fraction of astronauts experience postflight orthostatic intolerance (POI) during 10-min stand tests conducted on landing day. The average time that nonfinishers can stand is about 7 min. This phenomenon, including the delay in occurrence of presyncope, was studied with a five-compartment model of the cardiovascular system incorporating compartments for the heart/lungs, systemic arteries and cephalic, central, and caudal veins. The model included 28 independent parameters, including factors characterizing cardiac performance, vascular resistance, intrathoracic pressure, nonlinear venous compliance and circulating blood volume, and 13 dependent parameters, including cardiac output and cardiac and vascular compartment pressures and volumes. First, a sensitivity analysis of hemodynamic indicators of presyncope to independent parameters was performed. Results demonstrated that both cardiac output and arterial pressure were most sensitive to volume-related parameters, particularly total blood volume, and less sensitive to peripheral resistance. Next, a simulated postflight stand test confirmed that fluid loss due to capillary filtration, particularly from the caudal region where transmural pressure is high during standing, is a plausible mechanism of POI that also explains the delayed onset of symptoms in most astronauts. An accumulated drop in arterial pressure sufficient to compromise cerebral perfusion and, therefore, cause syncope was reached in about 7 min with a fluid loss of 280 mL. Finally, additional simulations showed that a 75% increase in peripheral resistance, similar to finishers of stand tests, was insufficient to overcome the loss of circulating fluid associated with capillary filtration, and extended the time that the modeled astronaut could stand by only about 1 min. It is therefore concluded that capillary filtration may play a key role in producing POI and that development of countermeasures should perhaps focus on reducing postflight capillary permeability or on stimulating volume-compensating mechanisms.
Related Concept Videos
Heart Failure II: Pathophysiology
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...