Related Experiment Video
Updated: Jul 14, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Usefulness of ventricular dyssynchrony measured using M-mode echocardiography to predict response to
Ernesto Díaz-Infante1, Marta Sitges, Bàrbara Vidal
1Department of Cardiology, Thorax Institute, Hospital Clinic, Institut d'Investigacions Biomèdiques August Pi I Sunyer, University of Barcelona, Barcelona, Spain.
Abstract:
There are discordant data about the utility of septal-to-posterior wall motion delay (SPWMD) assessed using M-mode echocardiography to predict an improvement with cardiac resynchronization therapy (CRT). Baseline SPWMD was measured using M-mode in a parasternal short-axis view in a series of 67 patients undergoing CRT and followed up after 6 months. Heart failure was caused by coronary artery disease in 27 patients. Clinical responders were patients who were alive, had not undergone heart transplantation, and also increased the distance walked in 6 minutes by >10%. Baseline SPWMDs were mean 155 +/- 113 ms and median 135. Thirty-four patients (51%) had an SPWMD >130 ms. At 6-month follow-up, there were 17 nonresponders. At baseline, there were no significant differences between patients with SPWMD >130 or <130 ms in age, drug therapy, permanent atrial fibrillation, New York Heart Association functional class, underlying cause of cardiomyopathy, QRS duration, left ventricular (LV) ejection fraction, LV dimensions, or neurohormonal activation (norepinephrine and atrial and brain natriuretic peptide). At 6-month follow-up, baseline SPWMD was not associated with clinical response, New York Heart Association functional class, distance walked in 6 minutes, LV reverse remodeling, or neurohormonal activation. SPWMD >130 ms was also not a predictor. In conclusion, SPWMD is not a good predictor of response to CRT.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Heart Failure IV: Classification and Diagnostic Evaluation
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Dysrhythmias II: Classification of Tachyarrhythmias
Cardiomyopathy II: Dilated Cardiomyopathy
Dysrhythmias VI: Management of Dysrhythmias