Related Experiment Video
Updated: Jul 14, 2026

In Vivo Assessment of Alveolar Macrophage Efferocytosis Following Ozone Exposure
Published on: October 22, 2019
High tidal volume mechanical ventilation with hyperoxia alters alveolar type II cell adhesion
Leena P Desai1, Scott E Sinclair, Kenneth E Chapman
1Department of Physiology, University of Tennessee Health Science Center, Memphis, Tennessee 38163, USA.
Abstract:
Patients with acute respiratory distress syndrome undergoing mechanical ventilation may be exposed to both high levels of stretch and high levels of oxygen. We hypothesized that the combination of high stretch and hyperoxia promotes loss of epithelial adhesion and impairs epithelial repair mechanisms necessary for restoration of barrier function. We utilized a model of high tidal volume mechanical ventilation (25 ml/kg) with hyperoxia (50% O(2)) in rats to investigate alveolar type II (AT2) cell adhesion and focal adhesion signaling. AT2 cells isolated from rats exposed to hyperoxia and high tidal volume mechanical ventilation (MVHO) exhibited significantly decreased cell adhesion and reduction in phosphotyrosyl levels of focal adhesion kinase (FAK) and paxillin compared with control rats, rats exposed to hyperoxia without ventilation (HO), or rats ventilated with normoxia (MV). MV alone increased phosphorylation of p130(Cas). RhoA activation was increased by MV, HO, and the combination of MV and HO. Treatment of MVHO cells with keratinocyte growth factor (KGF) for 1 h upon isolation reduced RhoA activity and restored attachment to control levels. Attachment and migration of control AT2 cells was significantly decreased by constitutively active RhoA or a kinase inactive form of FAK (FRNK), whereas expression of dominant negative RhoA in cells from MVHO-treated rats restored cell adhesion. Mechanical ventilation with hyperoxia promotes changes in focal adhesion proteins and RhoA in AT2 cells that may be deleterious for cell adhesion and migration.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Atelectasis II: Pathophysiology
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
