Related Experiment Video
Updated: Jul 14, 2026

3D Imaging of PDL Collagen Fibers during Orthodontic Tooth Movement in Mandibular Murine Model
Published on: April 15, 2021
Pseudodynamic MRI differs from natural opening of the temporomandibular joint
Rudolf Seemann1, Christian Czerny, Kurt Schicho
1University Hospital of Cranio-Maxillofacial and Oral Surgery, Medical University of Vienna, Vienna, Austria. rudolf.seemann@meduniwien.ac.at
Objective:
One step toward motion analysis of the temporomandibular joint is pseudodynamic magnetic resonance imaging (i.e., with stepwise mouth opening controlled by a Burnett device). This study intends to clarify whether and how pseudodynamic motion differs from natural motion. Furthermore, the fixing efficiency (i.e., the reliability of the mechanical connection to the jaw) of the Burnett device was tested.
Study Design:
In 10 patients we recorded pseudodynamic opening motions by means of MRI and optical tracking technology (as known from image-guided surgery) synchronously; natural opening motions by spatiotemporal tracking only. The MRI was used to allow for interpretation of the pseudodynamic motion as recorded by means of optoelectronic tracking.
Results:
In 3 subjects the pseudodynamic differed from the natural opening in occurrence of a loop (i.e., a short backward motion of the condyle during the opening process that results from the application of the Burnett device and does not correspond to a natural jaw movement). Fifty percent of the opening steps showed unintended motion and thus did not keep the mandible still during the MRI scan.
Conclusion:
A method was provided to detect motion during MRI scan using optoelectronic tracking. Pseudodynamic motion may differ from natural motion.