Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
Published on: January 10, 2025
Blood oxyhemoglobin saturation measurements by blue-green spectral shift
Kurt R Denninghoff1, Russell A Chipman, Lloyd W Hillman
1University of Arizona, Department of Emergency Medicine, Tucson, Arizona 85724, USA. kdenninghoff@aemrc.arizona.edu
Abstract:
Previous work describing a resilient method for measuring oxyhemoglobin saturation using the blue-green spectral shift was performed using cell free hemoglobin solutions. Hemoglobin solution and whole blood sample spectra measured under similar conditions in a spectrophotometer are used here to begin evaluating the impact of cellular scattering on this method. The blue-green spectral shift with changing oxyhemoglobin saturation was preserved in these blood samples and the blue-green spectral shift was relatively unaffected by physiological changes in blood pH (6.6, 7.1, and 7.4), path length through blood (100 and 200 microm), and blood hematocrit (19 to 48%). The packaging of hemoglobin in red blood cells leads to a decreased apparent path length through hemoglobin, and an overall decrease in scattering loss with increasing wavelength from 450 to 850 nm. The negative slope of the scattering loss in the 476 to 516-nm range leads to a +3.0 nm shift in the oxyhemoglobin saturation calibration line when the blue-green spectral minimum in these blood samples was compared to cell free hemoglobin. Further research is needed to fully evaluate the blue green spectral shift method in cellular systems including in vivo testing.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Transport in the Blood
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...