Related Experiment Video
Updated: Jul 13, 2026

Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water
Published on: June 9, 2014
An improved colorimetric method for chlorine dioxide and chlorite ion in drinking water using lissamine green B and
Barry V Pepich1, Teri A Dattilio, Patricia S Fair
1Shaw Environmental, Inc., 26 W. Martin Luther King Drive, Cincinnati, OH 45268, United States. pepich.barry@epa.gov
Abstract:
Lissamine Green B (LGB) was carefully selected as a potential candidate for the development of a new U.S. Environmental Protection Agency (EPA) method that is intended for use at water utilities to determine chlorine dioxide (ClO2) in drinking water. Chlorine dioxide reacts with LGB in aqueous solution to decrease the absorbance of LGB in direct proportion to the ClO2 concentration. LGB was confirmed to have adequate sensitivity, and to suffer less interference than other dyes reported in the literature. The stoichiometry for the reaction between LGB and ClO2 was found not to be 1:1 and is dependent on the LGB concentration. This required calibration of each LGB stock solution and prompted the investigation of alternate means of calibration, which utilized a horseradish peroxidase (HRP)-catalyzed conversion of chlorite ion (ClO2(-)) to ClO2. This approach allowed the simultaneous determination of ClO2(-) concentration, which is also required each day at water plants that use ClO2. Studies were conducted to characterize and carefully optimize the HRP-conversion of ClO2(-) to ClO2 in order to yield reaction conditions that could be accomplished in less than 30 min at modest cost, yet meet EPA's sensitivity and robustness requirements for routine monitoring. An assessment of method detection limit, linearity and slope (or sensitivity), precision, and accuracy in finished drinking water matrices indicated that this approach was suitable for publication as EPA Method 327.0.
More Related Videos
05:17Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples
Published on: July 28, 2016
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
Related Concept Videos
Redox Titration: Overview
Redox Titration: Iodimetry and Iodometry
Redox Titration: Other Oxidizing and Reducing Agents
Complexometric Titration: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...