Related Experiment Video
Updated: Jul 13, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Reconstructed versus real-time 3-dimensional echocardiography: comparison with magnetic resonance imaging
Carly Jenkins1, Rodel Leano, Jonathan Chan
1University of Queensland, Department of Medicine, Princess Alexandra Hospital, Ipswich Road, Brisbane, Q4102, Australia. cjenkins@soms.uq.edu.au
Background:
The accuracy, reproducibility, and test-retest reliability of 3-dimensional (3D) echocardiography (3DE) with 3D reconstruction (3DR) and real-time (RT) imaging (RT 3DE) exceed that of 2-dimensional echocardiography (2DE). However, image quality with RT 3DE is inferior to 2DE and we sought to determine whether this justified ongoing use of 3DR.
Methods:
Unselected patients (n = 30, 22 men, age 66 +/- 7 years) presenting to the echocardiography laboratory for left ventricular (LV) evaluation were studied with 2DE and RT 3DE; 3DR images were obtained using external localization. The 3D measurements and reconstructions were obtained offline. Magnetic resonance images (MRI) were obtained using true free induction, steady state precession during breath hold and 3D volumes and ejection fraction (EF) were measured using 3D software. A separate cohort of 20 patients (13 men, age 60 +/- 12 years) was measured for test-retest variation.
Results:
All echocardiographic measures underestimated LV volumes and EF compared with MRI, but this was least with RT 3DE. End-diastolic volume by MRI (168 +/- 54 mL) was underestimated by RT 3DE (-15 +/- 31, P = .02), 3DR (-26 +/- 33, P < .01), and 2DE (-57 +/- 40, P < .01). Similarly, end-systolic volume by MRI (86 +/- 50 mL) was underestimated by RT 3DE (-15 +/- 31, P = .02), 3DR (-26 +/- 33, P < .01), and 2DE (-57 +/- 40, P < .01). However, EF measurements were similar with each method. Test-retest variation was less and interobserver and intraobserver correlations were better with RT 3DE for volumes and EF, compared with 3DR and 2DE.
Conclusions:
Despite limitations of image quality, RT 3DE is the most feasible and accurate approach for LV volume and EF measurements and follow-up LV assessment in daily practice.
More Related Videos
07:11Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...