Related Experiment Video
Updated: Jul 13, 2026

Rapid Setup of Tissue Microarray and Tiled Area Imaging on the Multiplexed Ion Beam Imaging Microscope Using the Tile/SED/Array Interface
Published on: September 15, 2023
On-Board Imager-based MammoSite treatment verification
Jadwiga Wojcicka1, Rafael Yankelevich, Stephen Iorio
1York Cancer Center, Apple Hill Medical Center, Suite 94, 25 Monument Road, York, PA 17403, USA. jwojcicka@wellspan.org
This study introduces a filmless verification protocol for MammoSite brachytherapy using CT scans and an On-Board Imager (OBI). This method accurately assesses balloon placement and integrity, offering a rapid alternative to conventional simulators.
Area of Science:
- Radiation Oncology
- Medical Physics
- Brachytherapy
Background:
- Conventional simulators are increasingly absent in radiation oncology departments.
- Image-guided radiation therapy and virtual simulation are becoming standard practices.
- There is a need for efficient and precise verification methods in MammoSite brachytherapy.
Purpose of the Study:
- To develop and evaluate a CT-based protocol for MammoSite brachytherapy using an On-Board Imager (OBI) for daily verification.
- To assess the feasibility and accuracy of OBI-based simulation for MammoSite procedures.
- To establish a rapid, filmless verification process as an alternative to conventional simulators.
Main Methods:
- A protocol utilizing CT-based planning, a Source Position Simulator (SPS) with a Simulator Wire, and an OBI was developed.
- MammoSite balloon implantation was followed by CT imaging for evaluation.
- OBI fluoroscopy was used for daily verification of balloon integrity and dwell position coincidence.
Main Results:
- The OBI-based verification process is filmless, rapid (under 10 min), and precise.
- Balloon diameter correlated well (within 1 mm) between CT and OBI images.
- Balloon symmetry was accurately defined (1 mm accuracy) using OBI console tools.
Conclusions:
- OBI-based simulation is a feasible and effective alternative for MammoSite balloon evaluation and daily verification.
- The developed protocol ensures precision without undermining accuracy.
- This method streamlines the verification process, replacing the need for conventional simulators.