Prospective evaluation of the negative predictive value of V/Q SPECT using 99mTc-Technegas
Michel Leblanc1, Félix Leveillée, Eric Turcotte
1Department of Nuclear Medicine and Radiobiology, Centre Hospitalier Universitaire de Sherbrooke, Quebec, Canada. michel.leblanc@dr.cgocable.ca
Objective:
To verify the negative predictive value of pulmonary ventilation/perfusion scintigraphy with single photon emission computed tomography (V/Q SPECT) in ruling out pulmonary thromboembolism.
Methods:
V/Q SPECT using 99mTc-Technegas was performed on 584 patients to rule out pulmonary thromboembolism between October 2004 and July 2005. Pulmonary thromboembolism was defined as any clear-cut vascular mismatch, regardless of size. Indeterminate scans were defined as cases having matching vascular type defects with a corresponding X-ray abnormality, or cases with equivocal mismatches. Other patterns were considered negative for pulmonary thromboembolism. Outcome data was gathered >3 months after the scan. Absence of pulmonary thromboembolism was defined as any patient still alive at least 3 months after the scan, with no anticoagulation treatment and no proof of pulmonary thromboembolism by other techniques, either at the time of the scan or during follow-up, or death by other causes.
Results:
One hundred and eight patients (19%) had a positive pulmonary thromboembolism reading, 18 (3%) an indeterminate study, and 458 (78%) patients had a negative reading for pulmonary thromboembolism. There were 189 patients with an abnormal chest X-ray. The mean follow-up time was 165 days. Of the 458 patients classified as negative for pulmonary thromboembolism, patients receiving chronic anticoagulation for other causes were excluded from follow-up (n=53), which left 405 patients for final analysis. There were no pulmonary thromboembolism-related deaths in the negative group. Six patients were identified as false negatives. The negative predictive value is estimated at 98.5%.
Conclusion:
SPECT pulmonary scintigraphy using 99mTc-Technegas demonstrates a high negative predictive value and a low indeterminate rate.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET