Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Affinity Chromatography01:03

Affinity Chromatography

Affinity chromatography is a powerful technique extensively utilized for separating and purifying specific biomolecules from complex mixtures. It capitalizes on the highly selective binding between an analyte and its counterpart, such as antibody-antigen interactions. The counterpart is immobilized on the stationary phase, forming an affinity column. The stationary phase typically consists of solid support, such as agarose or porous glass beads, immobilizing the affinity ligand. The mobile...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Types Of Column Chromatography01:29

Types Of Column Chromatography

The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dynamic Filtering Approach for the Online Preconcentration of Nanoplastics Using Capillary Electrophoresis.

Analytical chemistry·2026
Same author

Determining the hydrodynamic diameters of nanoplastics <i>via</i> short-end capillary zone electrophoresis-Taylor dispersion analysis in tandem.

The Analyst·2025
Same author

A sensitive, selective, and rapid fluorescent probe for thiophenol detection with a broad linear range and simple synthesis.

Talanta·2025
Same author

A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples.

Biosensors·2024
Same author

Recovery of Berry Natural Products Using Pyrene-Based MOF Solid Phase Extraction.

Chemistry (Weinheim an der Bergstrasse, Germany)·2024
Same author

Development of Spiropyran Immobilization and Characterization Protocols for Reversible Photopatterning of SiO<sub>2</sub> Surfaces.

ACS omega·2024

Related Experiment Video

Updated: Jul 13, 2026

A Method for Selecting Structure-switching Aptamers Applied to a Colorimetric Gold Nanoparticle Assay
12:31

A Method for Selecting Structure-switching Aptamers Applied to a Colorimetric Gold Nanoparticle Assay

Published on: February 28, 2015

Aptamers as molecular recognition elements in chromatographic separations

Daniela Hutanu1, Vincent T Remcho

  • 1Department of Chemistry, Oregon State University, Corvallis, USA.

Advances in Chromatography
|July 14, 2007
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
09:33

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor

Published on: March 21, 2018

Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
11:44

Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B

Published on: January 19, 2022

Related Experiment Videos

Last Updated: Jul 13, 2026

A Method for Selecting Structure-switching Aptamers Applied to a Colorimetric Gold Nanoparticle Assay
12:31

A Method for Selecting Structure-switching Aptamers Applied to a Colorimetric Gold Nanoparticle Assay

Published on: February 28, 2015

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
09:33

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor

Published on: March 21, 2018

Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
11:44

Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B

Published on: January 19, 2022