Related Experiment Video
Updated: Jul 13, 2026

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Influence of surface roughness on mechanical strength of resin composite versus glass ceramic materials
Ulrich Lohbauer1, Frank A Müller, Anselm Petschelt
1Dental Clinic 1, Operative Dentistry and Periodontology, University of Erlangen-Nuremberg, Glückstr. 11, D-91054 Erlangen, Germany. lohbauer@dent.uni-erlangen.de
Objectives:
Clinical polishing leads to reduction of surface flaws sizes and thus to increased mechanical strength. The aim of the present work was to assess fracture strength of a resin composite and of a glass ceramic as a function of surface roughness and to relate the strength data to flaw sizes, microstructural and fractographic examinations.
Methods:
Specimens have manufactured out of a resin composite (Tetric EvoCeram, TEC) and out of glass ceramic material (IPS E.max Press, EMP). Different surface roughness levels have been induced using cutting, grinding and polishing techniques and quantified under CLSM. Fracture strength was measured in four-point bending and analyzed using Weibull statistics. Indentation fracture method was used to calculate fracture toughness. Critical flaw sizes were calculated and related to microstructure. Microstructural and fractographic examinations have been performed under SEM.
Results:
Fracture strength upon the glass ceramic material decreased from 441.4 to 303.3 MPa (R(a)=150 nm-1.5 microm) and upon the resin composite from 109.8 to 74.0 MPa (R(a)=300 nm-50 microm). EMP exhibited a fracture toughness of K(Ic)=4.14 MPam(0.5) and TEC of K(Ic)=1.89 MPam(0.5). Calculated crack lengths for EMP ranged from 28.1 microm (441.4 MPa) to 59.6 microm (303.3 MPa) and for TEC from 94.3 microm (109.8 MPa) to 207.0 microm (74.0 MPa).
Significance:
Dependency of fracture strength on surface roughness is neither determined by crystallite size of the glass ceramic material nor by filler sizes of the resin composite. No significant increase in fracture strength has been observed below 0.65 microm (1000 grit) in EMP. For TEC a threshold value might be determined below 2.1 microm (320 grit). Optimal polishing of a restoration right after placement is strongly recommended to keep an optimum strength performance through the whole clinical lifetime.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Bonding and Strength of Aggregate
Toughness and Hardness of Aggregate