Related Experiment Video
Updated: Jul 13, 2026

Stable Aqueous Suspensions of Manganese Ferrite Clusters with Tunable Nanoscale Dimension and Composition
Published on: February 5, 2022
Synthesis of some ferromagnetic composite resins and their metal removal characteristics in aqueous solutions
1Nuclear Chem. Department, Hot Labs. Center, Atomic Energy Authority, P.C. 13759, Cairo, Egypt. rsheha68@yahoo.com
Abstract:
In this study, a procedure for synthesis of new organic-inorganic magnetic composite resins was established. The procedure was based upon immobilization of magnetite (Mag) as a ferromagnetic material within the polymer poly(acrylic acid acrylonitrile) P(AA-AN) and the ion exchange resin (Amberlite IR 120). The produced magnetic resins, IR 120-PAN-Mag (R1) and P(AA-AN)-Mag (R2) were assessed as sorbents for Cr(VI). Various factors influencing the sorption of Cr(VI), e.g., pH, equilibrium time, initial concentration and temperature were studied. The sorption process was very fast initially and maximum sorption was achieved within 3h and pH 5.1. The kinetic of the system has been evaluated with pseudo first order model, second order model, Elovich model, intra-particle diffusion model and liquid film diffusion model. Chromium interaction with composite particles followed second-order kinetics with a correlation coefficient extremely high and closer to unity and rate constant (k(s)) has the values 1.68 x 10(-4) and 1.9 x 10(-4)g(mg(-1)min(-1)) for R1 and R2, respectively. The values of equilibrium sorption capacity (q(e)) are consistent with the modeled data and attain the range 893-951 mg g(-1). Kinetically, both pore diffusion and film diffusion are participating in ruling the diffusion of Cr(VI) ions. The sorption data gave good fits with Temkin and Flory-Huggins isotherm models. The isotherm parameters related to the heat of sorption are in the range 8-16 kJ mol(-1) which is the range of bonding energy for ion exchange interactions and so suggest an ion exchange mechanism for removal of Cr(VI) by the composite sorbents. The adsorption process was exothermic with DeltaH in the range of -73 to -97 kJ mol(-1). The negative values of Gibbs free energy confirm the feasibility and the spontaneous nature of Cr(VI) removal with these novel composites.
Related Concept Videos
Extraction: Advanced Methods
Ferromagnetism
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Precipitation and Co-precipitation

