Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Blood volume measurement as a tool in diagnosing syncope
Fetnat Fouad-Tarazi1, J Calcatti, R Christian
1Department of Cardiovascular Medicine, Hemodynamic and Neuroregulation Laboratory, Syncope Clinic, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA.
Background:
The cause of syncope remains unknown in 24% to 37% of cases even after standard diagnostic tests. Measuring blood volume may elucidate the mechanisms of syncope in the individual patient and prove helpful in determining optimal therapy. This report includes the largest set of blood volume measurements performed in syncope patients to date.
Methods:
We performed radioisotopic blood volume measurement (Daxor BVA-100) on 539 patients who presented to our center with syncope/presyncope of unclear etiology. There were 202 men and 337 women, ages 16 to 88 years; many were receiving treatment at the time they were referred to our center. We also measured blood pressure, heart rate, and cardiac index before and during tilt, with complete data available for 411 patients.
Results:
Blood volume derangements ranged from -32% to +116% deviation from normal. Hematocrit could not be used to predict volume status. Volume depletion was found in 241 (44.7%) patients and volume expansion was found in 63 (11.7%). Blood pressure, heart rate, and cardiac index before and during tilt did not correlate with any component of blood volume and could not be used to predict volume status.
Conclusions:
Syncope patients are heterogeneous with respect to blood volume, and blood volume derangements are common and are not identified through tilt table testing. Empirically prescribed pharmacological treatment for syncope is frequently inappropriate. Blood volume measurement should be included in syncope diagnosis.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...