Pulse wave analysis to assess systemic blood flow during mechanical biventricular support
Sabino Scolletta1, Igor D Gregoric, Luigi Muzzi
1Department of Cardiothoracic Anesthesia, University of Siena, Siena, Italy. scolletta@unisi.it
Perfusion
|July 18, 2007
Summary
Systemic blood flow monitoring is vital for mechanical circulatory support (MCS) patients. The pressure recording analytical method (PRAM) showed limitations with high-speed axial flow pumps due to nonpulsatile flow.
Area of Science:
- Cardiology
- Biomedical Engineering
- Critical Care Medicine
Background:
- Systemic blood flow measurement is critical for patients requiring mechanical circulatory support (MCS).
- Severe cardiogenic shock necessitates advanced hemodynamic monitoring.
- Ventricular assist devices (VADs) are crucial for supporting failing hearts.
Observation:
- A case study involving a 65-year-old female patient with severe cardiogenic shock receiving both left and right ventricular assist devices (LVAD and RVAD).
- Blood flow was assessed using ultrasonic flowmetry, continuous thermodilution, and the pressure recording analytical method (PRAM).
- PRAM, a pulse contour system, analyzes radial artery pressure waveforms for beat-by-beat systemic blood flow assessment.
Findings:
- At Jarvik pump speeds ≤10000 rpm, PRAM and thermodilution provided comparable blood flow values.
- At Jarvik pump speeds ≥11000 rpm, the aortic valve remained closed, resulting in nonpulsatile flow, rendering PRAM unable to provide blood flow data.
- This study represents the initial use of PRAM in a patient with combined VAD support.
Implications:
- PRAM's utility in monitoring systemic blood flow in MCS patients is limited, particularly with high-speed axial flow pumps causing nonpulsatile flow.
- Further research is needed to validate PRAM as a supplementary monitoring tool in VAD patients.
- Understanding the limitations of hemodynamic monitoring devices is essential for optimizing patient care in advanced heart failure.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: