Related Experiment Video
Updated: Jul 13, 2026

04:36
Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Rise in intraocular pressure during haemodialysis in a patient with reduced outflow facility
The British Journal of Ophthalmology
|July 20, 2007
Abstract
No abstract available in PubMed .
Related Concept Videos
Open Angle Glaucoma: Treatment
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
Hemodialysis II: Procedure and Complications
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Hemodialysis III: Nursing Management
The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this measurement...
Hemodialysis I: Introduction
Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Increased Intracranial Pressure l: Introduction
Intracranial hypertension is a sustained elevation of intracranial pressure (ICP) above 22 mm Hg. In supine adults, normal ICP is ~7–15 mm Hg.The rigid, nonexpandable cranium contains three components—brain tissue, blood, and cerebrospinal fluid (CSF)—that total ~1,700 mL in a typical adult: 1,400 mL brain (~80%), 150 mL blood (~10%), and 150 mL CSF (~10%). According to the Monro–Kellie doctrine, total intracranial volume is effectively fixed. When one component expands, CSF and venous blood...
