Vancomycin sensitivity and KOH string test as an alternative to gram staining of bacteria
K Arthi1, B Appalaraju, S Parvathi
1Department of Microbiology, PSG Institute of Medical Sciences and Research, Coimbatore - 641 004, Tamil Nadu, India.
Abstract:
Two hundred and eighteen bacterial isolates obtained from various clinical samples were subjected to Gram stain by conventional method. For all the isolates potassium hydroxide (KOH) string test and sensitivity to vancomycin were done. Gram positive bacteria showed 100% sensitivity to vancomycin as also 100% negativity for string test. Of the gram negative bacteria, 99.42% were resistant to vancomycin while 98.85% were positive for the string test. KOH and vancomycin tests are simple, inexpensive and can be used in addition to Gram staining for rapid identification of bacterial cultures.
Related Concept Videos
Differential Staining Technique
Special Staining Techniques
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...