An empirical characterization of the quality of DTI data and the efficacy of dyadic sorting
Nathan E Yanasak1, Jerry D Allison, Tom C-C Hu
1Department of Radiology, Medical College of Georgia, Augusta, GA 30912, USA. nyanasak@mcg.edu
Abstract:
Metrics calculated from images acquired using the diffusion tensor imaging (DTI) technique possess a systematic bias that depends on signal-to-noise ratio (SNR). Dyadic sorting provides a simple method for remediating some of this bias within a region(s) of interest (ROI). Although this bias and its removal using dyadic sorting have been studied previously within a theoretical framework, one can employ precise geometric knowledge of microstructures to perform an empirical comparison between expected DTI results and those measured with a scanner. In this project, the biasing effect of low SNR (approximately 1-10) on DTI eigenvalues was measured directly using water-filled capillary structures of two different sizes, and the magnitude of the corrective effect of dyadically sorting eigenvector-eigenvalue pairs was characterized. Multiple DTI series were acquired for determining DTI metrics at eight unique SNR values, using T(R) to vary signal intensity via T(1) contrast. Differences between the second and third eigenvalues, which should be equal for prolate geometry, ranged from approximately 23% to 45% and from 19% to 41% for large and small inner diameter capillaries after sorting eigenvalues by magnitude, and ranged from approximately 1% to 18% and from 1% to 4% after dyadic sorting. A high-resolution DTI series was used to observe the effect of ROI size on dyadic sorting. For restriction of diffusion on the scale of the small capillary at SNR approximately 18, an ROI with > or =50 pixels is adequate to determine fractional anisotropy to 99% accuracy, while larger ROI are required to resolve the two smaller eigenvalues to the same accuracy ( approximately 330-390 pixels). At low values of SNR, the iteration of dyadic sorting is suggested to achieve good accuracy. A method for the incorporation of empirical measurements into a bias-correction map, which would be useful for characterizing uncertainty and for reducing systematic bias in DTI data, is introduced.
More Related Videos
Related Concept Videos
Statistical Methods to Analyze Parametric Data: Student t-Test and Goodness-of-Fit Test
The Student's t-test is a statistical test that examines if there is a statistically significant difference between the means of two groups. This test is instrumental when dealing with data...
Detection of Gross Error: The Q Test
Properties of DTFT I
The linearity property of DTFTs is fundamental. If two discrete-time signals are multiplied by constants a and b respectively, and then combined to...
Kendall's Tau Test
A τ value of +1 indicates that...
Comparing Experimental Results: Student's t-Test
Properties of DTFT II
The frequency differentiation property is illustrated by considering a DTFT pair and differentiating both sides with respect to ω. Multiplying by j...