Related Experiment Video
Updated: Jul 13, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
High resolution scintimammography helps in differentiating benign from malignant findings in scintigraphic hot spots
Giuseppe De Vincentis1, Lucio Maria Porfiri, Margherita Betti
1Dept. cf Radiological Sciences University, La Sapienza, Rome, Italy.
Abstract:
Several efforts have been focusing on the development of detectors devoted to high solution (99m)Tc sestamibi scintimammography to improve sensitivity for non palpable lesions. To this aim new high resolution scintillation gamma camera was developed under the "Integiated Mammographic Imaging" project. The gamma camera, made by CAEN and Pol.Hi.Tech, has an overall dimension of 112x120x75mm3. It consists of an array of 1 in. PSPMTs Hamamatsu H8520-C12 closely packed, a NaI(T1) scintillation array (1.8x1.8x6mm(3) pixel) and a general purpose collimator. By this gamma camera a clinical experience on a few patients with breast cancer suspicion was performed. In this paper we show how high resolution approach allows to better categorize the lesions on the basis of the morphology of the spatial distribution of the radiotracer in the breast tissue. By comparing conventional and high resolution images of a young patient (29 y.o.) with breast cancer suspicion, it appears clear how the Anger, camera images showed a defined hot spot, highly suggestive of malignant lesion; on the contrary, the high resolution scan shown a large and inhomogeneous uptake area with the absence of clear and focal character of the uptake, to be considered as a probably non malignant lesions. This resuh was confirmed by byoptical findings that diagnosed the echographic findings as a benign inflammatory lesion.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Magnetic Resonance Imaging
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...