Comparison of image quality of different iodine isotopes (I-123, I-124, and I-131)
Erwann Rault1, Stefaan Vandenberghe, Roel Van Holen
1MEDISIP, ELIS Department, Ghent University, Ghent, Belgium. Erwann.Rault@ugent.be
Abstract:
I-131 is a frequently used isotope for radionuclide therapy. This technique for cancer treatment requires a pre-therapeutic dosimetric study. The latter is usually performed (for this radionuclide) by directly imaging the uptake of the therapeutic radionuclide in the body or by replacing it by one of its isotopes, which are more suitable for imaging. This study aimed to compare the image quality that can be achieved by three iodine isotopes: I-131 and I-123 for single-photon emission computed tomography imaging, and I-124 for positron emission tomography imaging. The imaging characteristics of each isotope were investigated by simulated data. Their spectrums, point-spread functions, and contrast-recovery curves were drawn and compared. I-131 was imaged with a high-energy all-purpose (HEAP) collimator, whereas two collimators were compared for I-123: low-energy high-resolution (LEHR) and medium energy (ME). No mechanical collimation was used for I-124. The influence of small high-energy peaks (>0.1%) on the main energy window contamination were evaluated. Furthermore, the effect of a scattering medium was investigated and the triple energy window (TEW) correction was used for spectral-based scatter correction. Results showed that I-123 gave the best results with a LEHR collimator when the scatter correction was applied. Without correction, the ME collimator reduced the effects of high-energy contamination. I-131 offered the worst results. This can be explained by the large amount of septal penetration from the photopeak and by the collimator, which gave a low spatial resolution. I-124 gave the best imaging properties owing to its electronic collimation (high sensitivity) and a short coincidence time window.
More Related Videos
07:23An Optimized Protocol for the Efficient Radiolabeling of Gold Nanoparticles by Using a 125I-labeled Azide Prosthetic Group
Published on: October 10, 2016
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Redox Titration: Iodimetry and Iodometry
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...